[2023] Use Valid Exam 2V0-41.20 by VCEEngine Books For Free Website [Q36-Q61]

Share

[2023] Use Valid Exam 2V0-41.20 by VCEEngine Books For Free Website

Free VCP-NV 2V0-41.20 Official Cert Guide PDF Download


VMware VCP-NV 2022 Exam Syllabus Topics:

SectionObjectives
Planning and Designing
Troubleshooting and Repairing- Identify the default log file locations of NSX-T Data Center components
- Compare and Contrast Tools Available for Troubleshooting
- Troubleshoot Common NSX Installation/Configuration Issues
- Troubleshoot Common NSX Component Issues
- Troubleshoot Common Connectivity Issues
- Troubleshoot Common physical infrastructure Issues
Performance-tuning and Optimizing Upgrades
Installing, Configuring, and Setting Up a VMware vSphere Solution- Outline the installation and preparation workflow of NSX-T Data Center
- Deploy and Configure NSX-T Data Center Environment
- Configure Hypervisor Networking [vSphere and KVM] for NSX-T Data Center
- Configure and manage Logical Switching Features
- Configure and manage Logical Routing Features
- Configure NSX-T Edge Nodes and Edge Cluster
- Configure NSX-T Data Center Network Services [Layer-3]
- Configure NSX Security Features
- Configure Service Insertion with NSX-T Data Center

 

NEW QUESTION 36
Which statement is true about an alarm in a Suppressed state?

  • A. An alarm can be suppressed for a specific duration in minutes.
  • B. An alarm can be suppressed for a specific duration in seconds.
  • C. An alarm can be suppressed for a specific duration in hours.
  • D. An alarm can be suppressed for a specific duration in days.

Answer: D

 

NEW QUESTION 37
Which statement is true about an alarm in a Suppressed state?

  • A. An alarm can be suppressed for a specific duration in minutes.
  • B. An alarm can be suppressed for a specific duration in hours.
  • C. An alarm can be suppressed for a specific duration in seconds.
  • D. An alarm can be suppressed for a specific duration in days.

Answer: B

Explanation:
https://docs.vmware.com/en/VMware-NSX-Intelligence/1.1/user-guide/GUID-EBD3C5A8-F9AB-4A22-BA40-92D61850C1E6.html
"If you move an alarm into a Suppressed state, you are prompted to specify the duration in hours. After the specified duration passes, the alarm state reverts to Open. However, if the system determines the condition has been corrected, the alarm state changes to Resolved." https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-EB1BB1D3-8892-4890-BE74-EF43CFC75F19.html

 

NEW QUESTION 38
Which NSX CLI command is used to check the GENEVE tunnel status on ESXi transport node?

  • A. get transport-node tunnel state
  • B. get host-switch <Host-Switch-Name> tunnel status
  • C. get host-switch <Host-Switch-Name> tunnels
  • D. get transport-node tunnel status

Answer: C

Explanation:
Reference:
https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html#get%20host-switch%20%3Chost-switch-name%3E%20tunnels

 

NEW QUESTION 39
Which three steps must be carried out to configure North-South / East-West Network Inspection? (Choose three.)

  • A. Service Insertion
  • B. Service Deployment
  • C. Service Registration
  • D. Service Consumption
  • E. Service Introspection

Answer: B,C,D

Explanation:
Use these steps to configure north-south and east-west Network Introspection:
1. Service Registration: Service registration makes a service available in the catalog.
2. Service Deployment: Deploy an instance of a registered service.
3. Service Consumption: Use services in a service chain and redirect traffic.
Taken from NSX-T ICM 3.0 Lecture Manual.

 

NEW QUESTION 40
Which CLI command on NSX Manager and NSX Edge is used to change NTP settings?

  • A. set ntp-server
  • B. get timezone
  • C. set timezone
  • D. et time-server

Answer: A

 

NEW QUESTION 41
An NSX administrator noticed that the nsxcli command times out after 600 secs of idle time.
Which CLI command disables the nsxcli time out value on NSX Manager?

  • A. set cli-timeout 1
  • B. set cli-timeout 0
  • C. set cli-timeout enabled
  • D. set cli-timeout disabled

Answer: B

Explanation:
Reference:
" https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html#set%20cli-timeout%20%3Ctimeout%3E
https://www.virten.net/2020/06/quick-tip-remove-nsx-t-ssh-and-http-session-timeout/

 

NEW QUESTION 42
In a NSX-T Data Center environment, an administrator is observing low throughput and congestion between the Tier-0 Gateway and the upstream physical routers.
Which two actions could address low throughput and congestion? (Choose two.)

  • A. Configure ECMP on the Tier-0 gateway.
  • B. Configure NAT on the Tier-0 gateway.
  • C. Add an additional vNIC to the NSX Edge node.
  • D. Configure a Tier-1 gateway and connect it directly to the physical routers.
  • E. Deploy Large size Edge node/s.

Answer: A,E

 

NEW QUESTION 43
An NSX administrator has configured a load balancer virtual server on a Tier-1 Gateway.
In order to advertise the load balancer virtual IP to the Tier-0 Gateway, which route advertisement configuration has to be done on the Tier-1 Gateway? (Choose two.)

  • A. Advertise All NAT Routes
  • B. All Static Routes
  • C. Information
  • D. Advertise All LB SNAT IP Routes
  • E. Advertise All LB VIP Routes

Answer: D,E

Explanation:
Explanation
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-EEBA627A-0860-477A-95

 

NEW QUESTION 44
Which NSX CLI command is used to check the GENEVE tunnel status on ESXi transport node?

  • A. get transport-node tunnel state
  • B. get host-switch <Host-Switch-Name> tunnel status
  • C. get host-switch <Host-Switch-Name> tunnels
  • D. get transport-node tunnel status

Answer: C

 

NEW QUESTION 45
An NSX administrator is creating a NAT rule on a Tier-0 Gateway configured in active-standby high availability mode.
Which two NAT rule types are supported for this configuration? (Choose two.)

  • A. Destination NAT
  • B. Source NAT
  • C. Reflexive NAT
  • D. 1:1 NAT
  • E. Port NAT

Answer: A,B

 

NEW QUESTION 46
When a stateful service is enabled for the first time on a Tier-0 Gateway, what happens on the NSX Edge node?

  • A. DR is instantiated and automatically connected with SR.
  • B. SR and DR doesn't need to be connected to provide any stateful services.
  • C. SR is instantiated and automatically connected with DR.
  • D. SR and DR is instantiated but requires manual connection.

Answer: C

 

NEW QUESTION 47
Which command is used to change the NSX CU administrator password?

  • A. set user admin password <password> old-password <old-password>
  • B. set user administrator password <old-password> <new-password>
  • C. set user administrator password <password> old-password <old-password> To change the password of an account run: set user admin password my-new-pwd old-password my-old-pwd
  • D. set user admin password <old-password> <new-password>

Answer: A

 

NEW QUESTION 48
When running nsxcli on an ESXi host, which command will show the Replication mode?

  • A. get logical-switch <Local-Switch-UUID> status
  • B. get logical-switch <Logical-Switch-UUID>
  • C. get logical-switches
  • D. get logical-switch status

Answer: B

Explanation:
Explanation
https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/82646

 

NEW QUESTION 49
Which two statements are true about the implementation of multicast in NSX-T Data Center? (Choose two.)

  • A. Multicast is supported in ESXi and KVM transport nodes.
  • B. Tier-0 gateways can be the Rendezvous Point.
  • C. IGMP Snooping is used to populate multicast forwarding tables.
  • D. Multicast routing is implemented with PIM Sparse-Mode.
  • E. An Edge can be the Rendezvous Point.

Answer: C,D

Explanation:
Explanation
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/nsxt_30_admin.pdf

 

NEW QUESTION 50
Which network tool cloud an administrator use on an ESXi 7 host to capture packets when troubleshooting connectivity issues?

  • A. Wireshark
  • B. net-stats
  • C. pktcap-uw
  • D. tcpdump

Answer: C

 

NEW QUESTION 51
Where are Distributed Firewall logs containing access decisions stored?

  • A. NSX API
  • B. NSX Edge
  • C. Hypervisor transport node
  • D. NSX Manager

Answer: D

 

NEW QUESTION 52
An NSX administrator has configured a KVM hypervisor as a transport node. Which kernel module on KVM implements a N-VDS?

  • A. dyswitch
  • B. openvswitch
  • C. nsx-vswitch
  • D. etherswitch

Answer: B

 

NEW QUESTION 53
An NSX administrator has deployed an NSX Edge on a bare-metal server.
Which command registers the NSX Edge with the NSX Manager?

  • A. join policy-manager <nsx-manager-ip> username root password <root-password> thumbprint <nsx-manager-thumbprint>
  • B. join management-cluster <nsx-cluster-IP> username admin password <admin-
    password> thumbprint <nsx-manager-thumbprint>
  • C. join management-plane <nsx-nanager-ip> username admin password <admin-password> thumbprint <nsx-manager-thumbprint>
  • D. join cluster <nsx-cluster-IP> username root password <root-password> thumbprint
    <nsx-manager-thumbprint>

Answer: C

 

NEW QUESTION 54
An NSX administrator has configured a load balancer virtual server on a Tier-1 Gateway.
In order to advertise the load balancer virtual IP to the Tier-0 Gateway, which route advertisement configuration has to be done on the Tier-1 Gateway? (Choose two.)

  • A. Advertise All NAT Routes
  • B. All Static Routes
  • C. Information
  • D. Advertise All LB SNAT IP Routes
  • E. Advertise All LB VIP Routes

Answer: D,E

Explanation:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-EEBA627A-0860-477A-95A7-7645BA562D62.html

 

NEW QUESTION 55
How is the RouterLink port created between a Tier-1 Gateway and Tier-0 Gateway?

  • A. Manually create a Segment and connect to both Tier-1 and Tier-0 Gateways.
  • B. Automatically created when Tier-1 is connected with Tier-0 from NSX UI.
  • C. Manually create a Logical Switch and connect to bother Tier-1 and Tier-0 Gateways.
  • D. Automatically created when Tier-1 is created.

Answer: B

Explanation:
Reference:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-3F163DEE-1EE6-4D80-BEBF-8D109FDB577C.html

 

NEW QUESTION 56
Which command is used to set the NSX Manager's logging-level to debug mode for troubleshooting?

  • A. set service manager logging-level debug
  • B. set service nsx-manager logging-level debug
  • C. set service nsx-manager log-level debug
  • D. set service manager log-level debug

Answer: A

Explanation:
https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html

 

NEW QUESTION 57
Which command is used to display the network configuration of the Tunnel Endpoint (TEP) IP on a bare metal transport node?

  • A. ifconfig
  • B. ipconfig
  • C. debug
  • D. tcpdump

Answer: A

Explanation:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/installation/GUID-B7E7371E-A9F6-4880-B184-E00A62C0C818.html

 

NEW QUESTION 58
Which two choices are use cases for Distributed Intrusion Detection? (Choose two.)

  • A. Gain insight about micro-segmentation traffic flows.
  • B. Use agentless antivirus with Guest Introspection.
  • C. Quarantine workloads based on vulnerabilities.
  • D. Identify security vulnerabilities in the workloads.
  • E. Identify risk and reputation of accessed websites.

Answer: C,D

 

NEW QUESTION 59
How is the intra-tier transit link connection created between SR and DR for a Tier-0 Gateway?

  • A. Manually create external uplink interface and mark it as transit.
  • B. Manually create a gateway interface and mark it as transit.
  • C. Automatically created when SR is initialized.
  • D. Automatically created when DR is created.

Answer: C

Explanation:
Reference: https://blogs.vmware.com/networkvirtualization/2018/01/nsx-t-routing-part-2.html/

 

NEW QUESTION 60
When running nsxcli on an ESXi host, which command will show the Replication mode?

  • A. get logical-switch <Local-Switch-UUID> status
  • B. get logical-switch <Logical-Switch-UUID>
  • C. get logical-switches
  • D. get logical-switch status

Answer: B

 

NEW QUESTION 61
......

VMware 2V0-41.20 Official Cert Guide PDF: https://torrentpdf.vceengine.com/2V0-41.20-vce-test-engine.html