D-PEMX-DY-23 Dumps - Kickstart your Career with Real Updated Questions [Q70-Q88]

Share

D-PEMX-DY-23 Dumps - Kickstart your Career with Real  Updated Questions

Earn Quick And Easy Success With D-PEMX-DY-23 Dumps

NEW QUESTION # 70
An administrator is about to perform a firmware update on an MX9116n switch OS 10 from the CLI.
The latest OS 10 switch firmware image has been downloaded and their TFTP server is set up. Upon logged in with administrator credentials on the switch, which command should be used to start the update procedure?

  • A. firmwaredownload tftp://server-ip/imagename
  • B. install tftp://server-ip/imagename
  • C. upgrade tftp://server-ip/imagename
  • D. fwupdate tftp://server-ip/imagename

Answer: B


NEW QUESTION # 71
What can be used as the firmware update source for OME-M within an MX chassis?

  • A. Server Update Utility
    Baseline from a Catalog
  • B. Dell Update package
    System Live Image (SLI)
  • C. Dell Update Package
    Baseline from a Catalog
  • D. Server Update Utility
    System Live Image (SLI)

Answer: C


NEW QUESTION # 72
Which feature requires an iDRAC Enterprise license for a compute sled on a PowerEdge MX7000 chassis?

  • A. Last Crash Screen
  • B. Storage Management
  • C. iDRAC Service Module
  • D. Remote file share

Answer: D


NEW QUESTION # 73
What is the maximum supported drive configuration on a PowerEdge MX840c compute sled?

  • A. 4 x 2.5" drives and 2 x 3.5" drives
  • B. 6 x 3.5" drives
  • C. 2 x 2.5" drives and 4 x 3.5" drives
  • D. 8 x 2.5" drives

Answer: D


NEW QUESTION # 74
What are the required components for a PowerEdge MX7000 Minimum to POST configuration?

  • A. Two power supply units
    One compute sled
    One input output module
    Two management modules
    Five front fans and four rear fans
  • B. Two power supply units
    One compute sled
    One input output module
    One management module
    Four front and five rear fans
  • C. One power supply unit
    One compute sled
    One input output module
    One management module
    Two front fans and two rear fans

Answer: C


NEW QUESTION # 75
What are two considerations when adding an MX760c in a chassis running OME-M firmware earlier than v2.0?
(Select 2)

  • A. If the iDRAC of the existing sleds is not at a supported level, ATMOS cannot calculate the maximum cooling.
  • B. If the MX760c is not a thermally challenged system, the sled is going to run as designed.
  • C. If the MX760c is a thermally challenged system, the maximum supported ambient temperature cannot be reduced.
  • D. All the fans on the PowerEdge MX7000 must be Silver Grade.

Answer: A,C


NEW QUESTION # 76
Which network fabric connects directly to the chassis midplane?

  • A. Fabric D
  • B. Fabric B
  • C. Fabric A
  • D. Fabric C

Answer: D


NEW QUESTION # 77
Refer to the exhibit.

A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chassis configuration. The customer can only access half of the network ports, even though the quad-port cards are visible in the iDRAC.
What actions are required to resolve the problem?

  • A. Reboot the switches.
    Adjust the switch configuration to use the new ports.
  • B. Reseat all the switches.
    Adjust the switch configuration to use the new ports.
  • C. Install a new 200G cable from port 3 on the MX7116n in chassis 2 slot A1 into port 19 on the MX9116n in chassis 1 slot A1.
    Do the same for the switches in slots A2.
    Adjust the switch configuration to use the new ports.
  • D. Do a virtual reseat of all the MX740c sleds.
    Update the firmware on all the quad port network cards.
    Adjust the switch configuration to use the new ports.

Answer: C


NEW QUESTION # 78
Which SmartFabric Services Engine component is responsible for managing requested changes for the specific switching node?

  • A. External Fabric Manager
  • B. SFS Controller
  • C. Fabric Agent

Answer: C


NEW QUESTION # 79
An administrator is asked to install and power-on a new MX740c sled in an MX7000 chassis. The administrator inserts the sled and presses the power button. They notice that the power button LED is blinking green. After a short time power button turns to solid green and the server finally turns on.
What operation was in progress when the power button was blinking green?

  • A. iDRAC was updating firmware
  • B. Lifecycle Controller was taking firmware inventory
  • C. iDRAC was booting
  • D. Lifecycle Controller update was in progress

Answer: C


NEW QUESTION # 80
What are the correct CLI commands to configure the management IP Address on either the MX9116n or the MX5108n switches running SmartFabric OS10?

  • A. interface vlan 4020
    no ip address
    ip address 192.168.1.10/24
    no shutdown
    exit
    management route 0.0.0.0/0 192.168.1.1
  • B. interface mgmt 1/1/1
    no ip address
    ip address 192.168.10.10/24
    no shutdown
    exit
    management route 0.0.0.0/0 192.168.10.1
  • C. interface vlan 4020
    no ip address
    ip address 192.168.10.10/24
    no shutdown
    exit
    interface mgmt 1/1/1
    no shutdown
    exit
    management route 0.0.0.0/0 192.168.10.1
  • D. interface vlan 4020
    no ip address
    ip address 192.168.1.10/24
    no shutdown
    exit
    interface mgmt 1/1/1
    no ip address
    ip address 192.168.1.10/24
    no shutdown
    exit
    management route 0.0.0.0/0 192.168.1.1

Answer: D


NEW QUESTION # 81
Which MX7000 component is responsible for Fabric Consistency Check?

  • A. Management Module
  • B. iDRAC
  • C. Fabric Switching Engine
  • D. Lifecycle Controller

Answer: A


NEW QUESTION # 82
A new administrator has just taken over an MX7000 Multi-Chassis Management Group and two-racks of PowerEdge servers. The previous administrator no longer works at the company and is not available.
No one knows the password for the OME-M interface and the default password is not working.
What must be used to reset the password?

  • A. Management Module jumpers
  • B. Left ear control panel.
  • C. RACADM using a serial connection
  • D. iDRAC for one of the compute sleds.

Answer: A


NEW QUESTION # 83
Which uplink configuration combination of the Top of the Rack Switch and the MX7000 Management Module is supported?

  • A. 100 Mbps (Auto negotiation ON) and Auto negotiation OFF
  • B. 100 Mbps (Auto negotiation OFF) and Auto negotiation ON
  • C. 100 Mbps (Auto negotiation OFF) and Auto negotiation OFF

Answer: C


NEW QUESTION # 84
Why is the backup lead configuration important in an MCM Group?

  • A. The backup chassis is promoted automatically if the lead chassis fails.
  • B. This configuration allows configuration changes from the backup chassis.
  • C. The backup lead chassis facilitates management of systems when the existing lead chassis fails.
  • D. The configuration allows sharing of the lead chassis IOMs and Management Module databases.

Answer: C


NEW QUESTION # 85
In SmartFabric mode, what is the recommended maximum number of VLANs per server port on an MX7000 switch?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 86
Which three components store an MX7000 chassis service tag and MAC address configuration?
(Select 3)

  • A. LCD Panel
  • B. Chassis Luggage Tag
  • C. Management Module
  • D. Right Control Panel
  • E. Fabric Switching Engine

Answer: A,C,D


NEW QUESTION # 87
A customer wants to change the switch operating mode from SmartFabric mode to Full Switch mode.
After deleting the fabric in OME-M, what configuration is retained on the switch?

  • A. admin password, hostname, management IP Address, and the VLAN database
  • B. admin password, hostname, management IP Address, and all port breakout configuration
  • C. admin password, hostname, management IP Address, and the VLT domain configuration
  • D. admin password, hostname, and management IP Address

Answer: D


NEW QUESTION # 88
......

Free D-PEMX-DY-23 pdf Files With Updated and Accurate Dumps Training: https://torrentpdf.vceengine.com/D-PEMX-DY-23-vce-test-engine.html